7  Pull up and remove the electrical box.
1. Electrical box cover.
2. Two screws.

 
Removing Display PCB
1  Remove the pipe cover following
2  Remove 1 fixing screw and remove the terminal cover.
3  Disconnect all the wiring connected to the display PCB.
4  Hold the upper part of 4 holders with long nose pliers and remove the display PCB.
1. Display PCB (PWB2).
2. Terminal cover.
3. Long nose pliers.
4. Display PCB.
N O T E
DO NOT touch electrical components on the PCB. Pay attention not to bend or apply much force onto PCB in order
to avoid PCB failure.
N O T E
1  To connect wiring at reassembling ensure that the terminal numbers and wiring mark band codes are matched.
Incorrect wiring may result in malfunction or damage of electrical components.
2  Different dip switch setting shall be applied for each model when the electrical box is replaced; See chapter 8
"Troubleshooting".
3  Pay attention not to clamp any wiring between plates or electrical components when closing electrical box
cover or front cover at reassembling.