Entering Adjustment and Linearization Weights

Purpose
Entering adjustment and linearization weights.
Setup Information
The Service mode must be activated in order for linearization weights to be
entered under menu items 1.18.2 to 1.18.5 (see page 20).
Adjustment and linearization weights can be entered in the Setup menu under
WP-1 for the first weighing platform and COm1 / WP-2, UNICOM / WP-2 or
COm-WP for the second weighing platform. The settings are made in the
corresponding Setup menu under menu item 1.18.
The Service mode does not have to be activated in order for external user-
defined adjustment weights to be entered under menu item 1.18.1.
The adjustment and linearization weights must be entered in the unit selected
for the ADC configuration under menu item 11.8.
Procedure
Activate the Service mode (only necessary if linearization weights are going to
t
be entered)
Select the weighing platform.
t
Enter the external user-defined adjustment weight under menu item 1.18.1
t
Enter the external linearization weight under menu items 1.18.2 to 1.18.5.
t
Menu structure for entering the adjustment and linearization weights
HND.XTEntering the adjustment and linearization weights
Entering external user-defined adjustment weight (Service mode not required)
LIN. WT.1 Entering the lin. weight 1
LIN. WT.2 Entering the lin. weight 2
LIN. WT.3 Entering the lin. weight 3
LIN. WT.4 Entering the lin. weight 4
Function Allocation of the
The J key is usually used for the calibration/adjustment function. For detailed
Purpose
information about calibration and adjustment, see "Operation" starting on page 45.
The following additional functions can be allocated to the key when the Service
mode is activated:
External linearization with default weights (menu item 1.9.6)
External linearization with the linearization weights (menu item 1.9.7) entered
under menu item 1.18
Internal linearization (for WP-2 only) (menu item 1.9.5)
Set preload function (menu item 1.9.8)
Clear preload function (menu item 1.9.9)
Once linearization has been completed, or after a preload has been set or deleted
3
the function of the J key must be reallocated back to its original function in the
Setup menu, e.g. external calibration/adjustment with default weights (see menu
item 1.9).
Menu structure for the function allocation of the J key
CAL./ADJ. Calibration, adjustment
Ext. calibration/adjustment with default weights (Service mode not required)
Ext. calibration/adjustment with user-defined weights
(Entry under 1.18, Service mode not required)
CAL.INT Internal linearization (for WP-2 only)
CAL.EXT External linearization with default weights
CAL.E.USR. External linearization with user-defined weights (entered under 1.18)
SET.PREL. Setting the preload
DEL.PREL. Clearing the preload
BLOCKED Key blocked
Confi guring Weighing Platforms
Key
J
Operating Instructions Combics Indicators
1.18.
1.18.1
1.18.2
1.18.3
1.18.4
1.18.5
1.9.
1.9.1
1.9.3
1.9.5
1.9.6
1.9.7
1.9.8
1.9.9
1.9.10
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combics caw2pCombics caw2sCombics cah1Combics caw1s

Table of Contents