3.10.2 TRANSFER BELT CLEANING UNIT

NOTE: After replacing the transfer belt cleaning unit, reset the maintenance
counter, SP7-804-17.
[A]
While pushing the lever, pull out the transfer belt cleaning unit [A] ( x 1).
NOTE: 1) The blade [B] may damage the belt if you do not keep pushing the lever.
2) When reassembling, check that the transfer unit release lever is put
back to the original position (
After replacing the transfer belt cleaning unit, perform forced line position
adjustment (SP5-993-002 or  > Maintenance > Color Registration).
SM
TRANSFER AND PAPER TRANSPORT UNIT
[B]
B146R165.WMF
3.8).
3-49