2 Design
 Derating at the light load
Voltage
Capacity
Necessity
[kW]
of derating
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
200-V class
22 kW
100
95
90
55 kW
85
80
75
70
65
60
55
0.5
2
4
Carrier frequency [kHz]
2 - 8
200-V class
Light load mode
Max. carrier
frequency fc
[kHz]
No
12
No
12
No
12
No
12
Yes
6
No
12
No
12
Yes
7
Yes
8
Yes
6
Yes
5
Yes
8
Yes
3
Yes
8
Yes
3
11 kW 15,45 kW
3.7,18.5 kW
30 kW
37 kW
6
8
10
12
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
Derating at
Necessity of
fc = 12 kHz
derating
100%
No
100%
No
100%
No
100%
No
90%
Yes
(17.6 A max.)
100%
No
100%
No
90%
No
(52.2 A max.)
90%
No
(65.7 A max.)
90%
Yes
(76.5 A max.)
90%
Yes
(101.7 A max.)
80%
Yes
(112.0 A max.)
75%
Yes
(126.7 A max.)
90%
Yes
(189.0 A max.)
90%
Yes
(243.0 A max.)
Yes
Yes
Yes
Yes
400-V class
110 kW
75 kW
100
95
90
85
132 kW
80
75
90 kW
70
65
60
55
0.5
2
4
6
8
Carrier frequency [kHz]
400-V class
Light load mode
Max. carrier
Derating at
frequency fc
fc = 12 kHz (8 kHz
[kHz]
for 75 kW or more)
12
100%
12
100%
12
100%
12
100%
10
90%
(9.9 A max.)
12
100%
12
100%
12
100%
12
100%
8
95%
(40.8 A max.)
8
90%
(51.3 A max.)
10
80%
(56.0 A max.)
9
90%
(76.5 A max.)
8
80%
(84.0 A max.)
6
75%
(101.2 A max.)
7
90%
(144.0 A max.)
3
80%
(156.0 A max.)
4
85%
(195.5 A max.)
3
70%
(203.0 A max.)
3.7 kW
37 kW
18.5 kW
22 kW
30 kW
55 kW
45 kW
10
12