7 Detailed Functions
Multi-function Input Operation Selection
• The multi-function input terminals can be set to either NO (Normally open contact) or NC (Normally
closed contact) individually.
Parameter No.
C011
C012
C013
C014
C015
C016
C017
C018
C019
Related functions
7 - 110
Function name
Multi-function Input S1
Operation Selection
Multi-function Input S2
Operation Selection
00: NO (Normally open contact)
Multi-function Input S3
01: NC (Normally closed contact)
Operation Selection
• Each multi-function input terminal
Multi-function Input S4
Operation Selection
Multi-function Input S5
Operation Selection
Multi-function Input S6
Operation Selection
Multi-function Input S7
Operation Selection
• The terminal allocated to 18 (RS:
Multi-function Input S8
Operation Selection
Forward RUN
Command FW
Operation Selection
C001 to C008
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
Data
S1 to S8 and the terminal FW can
be set individually to either an NO
contact or NC contact input
terminal.
NO contact: ON when closed, OFF
when open
NC contact: ON when open, OFF
when closed
Reset) cannot be set to NC contact.
Be sure to set NO contact.
Default data
Unit
00
00