Omron RX Series User Manual page 63

High-function general-purpose inverter
Hide thumbs Also See for RX Series:
Table of Contents

Advertisement

 Derating at the heavy load
Voltage
Capacity
Necessity
[kW]
of derating
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
200-V class
100
95
90
85
45,55 kW
80
75
70
65
60
55
0.5
2
4
Carrier frequency [kHz]
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
200-V class
Heavy load mode
Max. carrier
frequency fc
[kHz]
No
15
No
15
No
15
No
15
No
15
No
15
No
15
Yes
12
Yes
12
Yes
10
Yes
7
Yes
5
Yes
10
Yes
5
Yes
5
22 kW
11 kW
15 kW
18.5 kW
30 kW
37 kW
6
8
10
12
14
15
Derating at
Necessity of
fc = 15 kHz
derating
100%
No
100%
No
100%
No
100%
No
100%
No
100%
No
100%
No
90%
No
(41.4 A max.)
95%
Yes
(60.8 A max.)
90%
Yes
(68.4 A max.)
70%
Yes
(66.5 A max.)
80%
Yes
(96.8 A max.)
75%
Yes
(108.7 A max.)
70%
Yes
(127.4 A max.)
70%
Yes
(154.0 A max.)
Yes
Yes
Yes
Yes
400-V class
90 kW
75 kW
100
95
90
85
80
132 kW
75
70
65
110 kW
60
55
0.5
2
4
6
8
Carrier frequency [kHz]
2 Design
400-V class
Heavy load mode
Max. carrier
Derating at
frequency fc
fc = 15 kHz (10 kHz
[kHz]
for 75 kW or more)
15
100%
15
100%
15
100%
15
100%
15
100%
15
100%
15
100%
15
100%
14
95%
(30.4 A max.)
10
90%
(34.2 A max.)
6
75%
(36.0 A max.)
10
75%
(43.5 A max.)
8
80%
(60.0 A max.)
9
75%
(68.2 A max.)
6
60%
(67.2 A max.)
6
85%
(126.7 A max.)
4
75%
(132.0 A max.)
6
70%
(151.9 A max.)
3
60%
(156.0 A max.)
45 kW
30 kW
15 kW
18.5 kW
37 kW
22 kW
55 kW
10
12
14
15
2
2 - 7

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents