Omron E7 Manual

Omron E7 Manual

G7/f7/l7/e7 inverter plc
Hide thumbs Also See for E7:

Advertisement

3G3RV-P10ST@-E
The OMRON PLC technology embedded in
the OMRON Yaskawa inverter family
• OMRON PLC programmability in the
OMRON Yaskawa inverters.
• Flexibility and intelligence in the OMRON Yaskawa
inverter family.
• Wireless installation and seamless access to the
inverter parameters and analogue/digital inputs and
outputs.
• OMRON Compobus/S fieldbus inside. Thus, able to
control up to 256I/O's.
• Easy to integrate in the automation world:
DeviceNet type available.
• Standard OMRON tools can be used for program-
ming and commissioning.
• Ideal for applications like:
• Pump sequencing, remote control, water
treatment,etc together with the HVAC inverter:
E7&E7 IP54.
• Lift as control sequence inside, using the lift
inverter: L7.
• Cranes, winding/rewinding, position control, oth-
ers combined with the powerful flux vector control
inverter: F7Z.
• General purpouse using the high technology of
G7 3-Level vector control.

System configuration

G7/F7/L7/E7 inverter PLC
RS-232C
RS-422
DeviceNet
CX-One
Varispeed + PLC
CompoBus/S communication path
16 of 32 slaves max.
(CX-Drive)
(CX-Programmer)
HMI interface
Other serial devices
Terminator
365

Advertisement

Table of Contents
loading

Summary of Contents for Omron E7

  • Page 1 • OMRON Compobus/S fieldbus inside. Thus, able to control up to 256I/O's. • Easy to integrate in the automation world: DeviceNet type available. • Standard OMRON tools can be used for program- ming and commissioning. • Ideal for applications like: • Pump sequencing, remote control, water treatment,etc together with the HVAC inverter: E7&E7 IP54.
  • Page 2: Specifications

    Type designation PLC inverter Inverter series Number of I/O's Specifications Specifications by product Item PLC core Inputs Outputs Peripheral port RS-232C port RS-422 port Calendar/clock Memory backup Compobus/S master interface Encoder interface DeviceNet Slave interface General specifications Item Rated power supply voltage Communications power supply voltage Power consumption Internal power...
  • Page 3 Analog volume Input time constant (ON response time = OFF response time) Clock/Calendar function Communication function G7/F7/L7/E7 inverter PLC Specifications 3G3RV-P10ST8-E 256 bits: LR 0000 to LR 1515 (words LR 00 to LR 15) 256 timers/counters (TIM/CNT 000 to TIM/CNT)
  • Page 4 Item Power-interruption hold function Memory backup (see notes 1 and 2.) Self-diagnostic function Program check Connected tools CX-programmer Programming console CX-drive Note: 1. The DM area, HR area, AR area, and counter values are backed up. If the backup battery or capacitor is discharged, the contents of these areas will be lost and the data values will revert to the defaults.
  • Page 5 A- and B-phase Z-phase Response frequency A- and B-phase Z-phase Circuit configuration A- and B-phase Z-phase G7/F7/L7/E7 inverter PLC Phase A Phase B Output LED COM (+) Internal circuits !Caution Do not apply voltage in excess of the maximum switching capacity to an output terminal.
  • Page 6 Operation CPU unit component descriptions 1. DIP switch 16. DeviceNet node address 13. FE connection 1. DIP switch • RS-232C and peripheral port settings Pin 1 Effective port settings The ports operate according to the settings in the (default) PLC setup. RS-232C port settings: DM 6645 to DM 6649 Peripheral port settings: DM 6650 to DM 6654 The ports operate with the standard communications...
  • Page 7 ON (left) Enabled Set this switch to ON only for double-ended connection to a host link network. G7/F7/L7/E7 inverter PLC 11. CompoBus/S port Terminal arrangement Use special flat cable or VCTF cable for the transmission lines that con- nect the nodes in the CompoBus/S I/O Link. (Special flat cables and VCTF cables cannot be combined in the same system.)
  • Page 8: Application Examples

    G7 + PLC Varispeed G7 is the OMRON Yaskawa solution using 3 level PWM control technology that provides lower surge voltage, low leakage current, low bearing current, low acoustic noise and better EMC. By combining with PLC option board, it is the ideal solution for winding/unwiding applications, handling / transfer / palletizer point-to-point positioning applications, press control applications, extruder control applications and pump applications for examples ..
  • Page 9 E7 + PLC Varispeed E7 is the OMRON Yaskawa solution for energy saving applications The E7 is designed for variable torque applications such as fans and centrifugal pumps. By combining with PLC option board, it is the ideal solution for water treatment, pump squencing, building automation and fan applications for example...
  • Page 10 L7 + PLC The L7 is the ultimate drive for lift applications up to 3m/s. High starting torque, silent operation, lift-specific operator interface and operation with both AC and PM motors are standard features of the L7 inverter. By combining with PLC option board, it is the ideal solution for controlling distributed I/O’s, lift cabin HMI, GSM modem to send alarms for example..
  • Page 11: Ordering Information

    A Varispeed Specifications The 3-Level control method inverter Flux vector control inverter The lift inverter The pumps and fans inverter Note: For detailed information please refer to Varispeed G7/F7/L7/E7 series section. Cables Specifications Computer connecting cable Programmable console cable Computer software...
  • Page 12 Compobus/S slaves Product Appearance Digital I/O terminals Relay output terminals Waterproof terminals Analog input terminal Analog output terminal Note: For detailed information about Compobus/S slaves, please refer to catalogue No. Y201-EN2-02 AS. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice.

Table of Contents