Precautions for Correct Use
Precautions for Correct Use
• The inverter calculates the capacitor life once every 10 minutes. If the power supply is turned
on/off more frequently than this cycle, the inverter cannot evaluate the capacitor life
successfully.
• If the Cooling Fan Operation (b092) is set to 01, the rotation speed of the cooling fan will be
evaluated as normal while the cooling fan is stopped.
Program Counter (DriveProgramming) [d023]
Use this function to display the line number of the program that is executed while a DriveProgramming
function is active.
For details, refer to "DriveProgramming User's Manual (I580)".
Parameter No.
d023
Program Number Monitor (DriveProgramming) [d024]
Use this function to display the program number of the downloaded DriveProgramming program.
However, you need to set a program number during programming.
For details, refer to "DriveProgramming User's Manual (I580)".
Parameter No.
d024
User Monitor 0 to 2 (DriveProgramming) [d025 to d027]
Use these functions to monitor the result of the calculation performed in the DriveProgramming
program.
For details, refer to "DriveProgramming User's Manual (I580)".
Parameter No.
d025
d026
d027
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
Function name
Program Counter
Function name
Program Number Monitor
Function name
User Monitor 0
User Monitor 1
User Monitor 2
Data
0 to 1024 (Displayed in increments of 1)
Data
0000 to 9999 (Displayed in increments
of 1)
Data
–2147483647 to 2147483647
(Displays MSB 4digits of
DriveProgramming execution result)
7 Detailed Functions
Default data
Unit
Default data
Unit
Default data
Unit
7 - 9
7