12-9-3 Connection Example

Power
supply
Precautions for Correct Use
Precautions for Correct Use
• Wind the phase R/S/T wire in the same direction.
• This noise filter can be used in the same manner on both the input and output side of the
inverter.
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
R
S
T
Install them as
close as possible.
Inverter
Motor
R/L1
U/T1
M
S/L2
V/T2
T/L3
W/T3