Omron RX Series User Manual page 68

High-function general-purpose inverter
Hide thumbs Also See for RX Series:
Table of Contents

Advertisement

2 Design
Removing Control Circuit Terminal Block
The following is the procedure for removing the control circuit terminal block.
To reinstall it, reverse the removal procedure.
1
Loosen the control circuit terminal block
fixation screws.
There are two control circuit terminal block
fixation screws, one for each side of the terminal
block.
2
Pull the control circuit terminal block PCB straight
forward to remove it.
Precautions for Correct Use
Precautions for Correct Use
Pull the control circuit terminal block PCB slowly. At this time, be careful not to bend or break the
connector pins and the PCB guide pins.
2 - 12
Fixation screw
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
PCB guide pin
PCB guide pin
Connector
(60 pins)
Fixation screw
Fixation screw (M3) x 2
PCB guide pin x 2