Stall prevention function

6.26.1 Power running stall continuous trip detection time

 : Power running stall continuous trip detection time
• Function
A function for preventing lifting gear from failing accidentally. If the stall prevention function is activated in
succession, the inverter judges that the motor has stalled and trips.
[Parameter setting]
Title

Power running stall continuous trip detection time

6.26.2 Regenerative braking stall prevention mode selection

 : Regenerative braking stall prevention mode selection
• Function
A function for preventing lifting gear from stopping in the wrong position. Only the function of preventing a
stall by maintaining the current constant during regenerative braking (deceleration stop) is deactivated.
[Parameter setting]
Title
Regenerative braking stall prevention

mode selection

6.26.3 Stall prevention control switching

 : Stall prevention control switching
• Function
The operation of the stall prevention control can be switched. Set
are displayed when acceleration and the deceleration are switched.
This parameter is effective at only V/f control mode(=,,).
[Parameter setting]
Title

Stall prevention control switching
Function
Output frequency [Hz]
Output current [%]

Function
Function
F-49
Adjustment range
~ sec.
"" trip
Time [s]
Time [s]

less than

Adjustment range
:Stall during regenerative braking
:Not stall during regenerative braking
when the overvoltage trip etc.
=1
Adjustment range
: Stall prevention control
: Stall prevention control 2
E6581442
Default setting

6
Default setting
Default setting