[25] Protection functions [2/2]
Communi
Title
cation
Function
No.
0622
Abnormal speed detection time
Overspeed detection frequency
0623
upper band
Overspeed detection frequency
0624
lower band
0625
Undervoltage detection level
0626
Overvoltage limit operation level 100~150%
0627
Undervoltage trip selection
Undervoltage (trip alarm)
0628
detection time
Regenerative power ride-through
0629
control level
0630
Braking answer waiting time
0631
Temperature detection
VI/II analog input wire breakage
0633
detection level
Annual average ambient
0634
temperature (calculation for part
replacement alarms)
Rush current suppression relay
0635
activation time
0637
PTC1 thermal selection
0638
PTC2 thermal selection
Braking resistance overload
0639
time (10 times of rated torque)
Step-out detection current level
0640
(for PM motors)
Step-out detection time (for PM
0641
motors)
Brake-equipped motor restart
0643
condition selection
Control power supply backup
0647
option failure monitoring
*1: For details, refer to Instruction Manual (E6581339) specified in Section 6.42.
Adjustment range
0.01~100.0 sec.
0.0:Disabled, 0.1~30.0Hz
0.0:Disabled, 0.1~30.0Hz
50~79%, 80: (auto mode)
0:Disabled
1:Enabled
0.01~10.00 sec.
55~100%
0.0:Disabled, 0.1~10.0 sec.
0:Standard (150%-60 sec.)
1:Estimation of temperature
0:None
1~100%
1:-10~+10°C
2:+11~+20°C
3:+21~+30°C
4:+31~+40°C
5:+41~+50°C
6:+51~+60°C
0.0~2.5 sec.
0:Deselect
1:Select
0:Deselect
1:Select
0.1~600.0 sec.
10~150
0.0:Not detect
0.1~25.0
0:Default (no waiting time for frequencies of 10Hz
and less)
1:Conditional (no waiting time for frequencies of
20Hz and less)
0:Control power supply not backed up
1:Control power supply backed up (alarm in the
event of a failure)
2:Control power supply backed up (tripping in the
event of a failure)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
0.01/0.01
0.01
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
1/1
80
Disabled
●/●
1/1
134
Disabled
●/●
1/1
0
Disabled
●/●
0.01/0.01
0.03
Disabled
●/●
1/1
75
Disabled
●/●
0.1/0.1
0.0
Enabled
●/●
1/1
0
Disabled
-
1/1
0
Enabled
●/●
1/1
3
Enabled
●/●
0.1/0.1
0.0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
0.1/0.1
5.0
Disabled
●/●
1/1
100
Disabled
-
0.1/0.1
0.0
Disabled
-
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
PM
V/f Constant Reference
Torque
control
control
●/●
●
●
6. 33. 13
●/●
●
●
6. 33. 13
●/●
●
●
6. 33. 13
●/●
●
●
6. 33. 15
-
●
●
6. 14. 2
●/●
●
●
6. 33. 15
●/●
●
●
6. 33. 15
●/●
●
●
6. 33. 16
-
-
-
6. 33. 17
-
-
-
5. 14
●/●
●
●
6. 33. 18
●/●
●
●
6. 33. 19
●/●
●
●
6. 33. 20
●/●
●
●
*1
●/●
●
●
*1
●/●
●
●
5. 19
-
●
-
6. 29
-
●
-
6. 29
●/●
●
●
6. 33. 23
●/●
●
●
6. 33. 24