[Terminal FM-related parameters]
Title
Function
FM terminal meter
selection
5
FM terminal meter
adjustment
Constant at the
time of filtering *4
FM voltage/current
output switching
FM output gradient
characteristic
FM bias adjustment
FM output filter
*1: Monitor adjustment level selected.
*2: "Compensated frequency" refers to the frequency actually sent from an inverter to the motor connected.
*3: Default setting value is adjusted for connection of frequency meters "QS60T".
(Between FM and CCA: Approx. 3.6V)
*4: The output current, input voltage, output voltage, compensated frequency, speed feedback (real-time value) torque, torque
current and exciting current output (FM/AM/pulse and monitor output) can be filtered.
Adjustment range
: Output frequency
: Frequency command value
: Output current
: Input voltage (DC detection)
: Output voltage
: Compensated frequency *2
: Speed feedback (real-time value)
: Speed feedback (1 second filter)
: Torque
: Torque command
: Torque current
: Exiting current
: PID feedback value
: Motor overload factor (OL2 data)
: Inverter overload factor (OL1 data)
: Regenerative braking resistance overload factor (OLr data)
: Regenerative braking resistor load factor (% ED)
: Input power
: Output power
: Optional AI2 input
: RR/S4 input
: VI/II input
: RX input
: Optional AI1 input
: FM output (Do not select this option.)
: AM output
: Fixed output 1
: Communication data output
: Fixed output 2
: Fixed output 3
: Cumulative input power
: Cumulative output power
: Gain display
~ :My function monitor 1~4
: Signed output frequency
: Signed frequency command value
: Signed compensated frequency
: Signed speed feedback (real-time value)
: Signed speed feedback (1 second filter)
: Signed torque
: Signed torque command
: Signed torque current
: Signed PID feedback value
: Signed RX input
: Signed optional AI1 input
~ :Signed fixed output 1~3
~ :Function none
: MON1 (Expansion I/O card2 option)
: MON2 (Expansion I/O card2 option)
: RP (Expansion I/O card2 option
–
msec, msec~ msec
:Voltage output (0~10V), :Current output (0~20mA)
:Negative gradient (downward-sloping),
:Positive gradient (upward-sloping)
– ~ %
:No filter,
:Filter approx. 10ms
:Filter approx. 15ms,
:Filter approx. 30ms
:Filter approx. 60ms,
:Filter approx. 120ms
:Filter approx. 250ms,
:Filter approx. 500ms
:Filter approx. 1s
E-28
E6581442
Adjustment
Default setting
level
(a)
(a)
(b)
(c)
(c)
(a)
(a)
(a)
(d)
(d)
(b)
(b)
(a)
(a)
(a)
(a)
(a)
(b)
(b)
(a)
(a)
(a)
(a)
(a)
(a)
(a)
–
–
–
–
(a)
(a)
–
*1
(a)
(a)
(a)
(a)
(a)
(d)
(d)
(b)
(a)
(a)
(a)
–
–
(a)
(a)
(a)
*3