Toshiba Tosvert VF-AS1 Instruction Manual page 311

The new high-performance inverter
Hide thumbs Also See for Tosvert VF-AS1:
Table of Contents

Advertisement

2) Standard specifications (large capacity types) [Note 1]
Item
Voltage class
Applicable motor (kW)
Applicable motor (HP)
Type
Form
Output capacity
(kVA) [Note 2]
Output current
(A)
Output voltage
Overload
current rating
Dynamic braking
circuit
Dynamic braking
resistor
Voltage-frequency
[Note 3]
Allowable
fluctuation
Protective method
Cooling method
Cooling fan noise (dBA)
Color
EMC filter
DC reactor
Item
Voltage class
Applicable motor (kW)
Applicable motor (HP)
Type
Form
Output capacity
(kVA) [Note 2]
Output current
(A)
Output voltage
Overload
current rating
Dynamic
braking circuit
Dynamic braking
resistor
Voltage-frequency
[Note 3]
Allowable
fluctuation
Protective method
Cooling method
Cooling fan noise (dBA)
Color
12
EMC filter
DC reactor
Note 1: For 200V-55kW, 400V-90kW or larger model, be sure to install DC reactor.
However, this is unnecessary for DC input specifications.
Note 2: Capacity is calculated at 220V for the 200V models and at 440V for the 400V models.
Note 3: An external power supply backup available (optional) (Type: CSP002Z)
Note 4: ±10% when the inverter is used continuously (load of 100%).
Note 5: Models, 200V-18.5kW and above, and 400V-22kW and above, do not have wiring port covers. They have
large openings, but there is no space to bend the external cables inside the unit.
Note 6: Three-phase 380~480V-50/60Hz for 4900PC
55
75
2550P
84
221
Three-phase 200V~240V (The maximum output voltage is equal to the input supply voltage.)
Voltage + 10% - 15% [Note 4]
61
90
110
132
125
150
200
4900PC
4110KPC
4132KPC
4160KPC
136
164
197
179
215
259
Three-phase 380V~480V (The maximum output voltage is equal to the input supply voltage.)
Built-in dynamic braking drive circuit
[Note 6]
Voltage + 10% - 15% [Note 4]
61
72
73
Specification
200V class
VFAS1-
150%-1 minute, 165%-2 sec.
Built-in dynamic braking drive circuit
An external braking resistor (optional)
Rating: Refer to 5.19.
Three-phase 200~240V-50/60Hz
Frequency ±5%
IP00 Open type (JEM1030) [Note 5]
Forced air-cooled
RAL7016
External filter (optional)
Attached DC reactor
Specification
400V class
160
200
220
280
250
300
350
450
VFAS1-
4200KPC
4220KPC
4280KPC
239
295
325
419
314
387
427
550
150%-1 minute, 165%-2 sec.
External dynamic braking circuit (optional)
An external braking resistor (optional)
Rating: Refer to 5.19.
Three-phase 380~440V-50Hz
Three-phase 380~480V-60Hz
Frequency ±5%
IP00 Open type (JEM1030) [Note 5]
Forced air-cooled
73
76
76
76
RAL7016
Built-in
Attached DC reactor
L-2
E6581442
75
100
2750P
109
285
72
355
400
500
550
600
700
4355KPC
4400KPC
4500KPC
511
578
717
671
759
941
76
76
78

Advertisement