Toshiba Tosvert VF-AS1 Instruction Manual page 263

The new high-performance inverter
Hide thumbs Also See for Tosvert VF-AS1:
Table of Contents

Advertisement

2. Basic parameter [2/4]
Communi
Title
cation
Function
No.

0015
V/f control mode selection
0016
Manual torque boost 1

0014
Base frequency 1

0409
Base frequency voltage 1

0011
Maximum frequency

0012
Upper limit frequency


0013
Lower limit frequency

0009
Acceleration time 1

0010
Deceleration time 1
RR/S4 input point 2

0213
frequency

0204
VI/II input point 2 frequency 0.0~ Hz
Preset speed operation

0018
frequency 1
Preset speed operation

0019
frequency 2
Preset speed operation

0020
frequency 3
Preset speed operation

0021
frequency 4
Preset speed operation

0022
frequency 5
Preset speed operation
0023

frequency 6
Preset speed operation
0024

frequency 7
Forward run/reverse run
selection (operation panel

0008
operation)
*1: Default values vary depending on the capacity.  See the table of K-48.
*2: Changing the parameter  enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).
*3: Inverter with a model number ending with -WN1: 60.0 -WP1: 50.0
Adjustment range
0:Constant torque characteristics
1:Voltage decrease curve
2:Automatic torque boost
3:Sensorless vector control 1 (speed)
4:Sensorless vector control 2 (speed/torque)
5:V/f 5-point setting
6:PM control
7:PG feedback control
8:PG feedback vector control
0.0~30.0%
25.0~500.0Hz
200V class:50~330V
400V class:50~660V
30.0~500.0Hz
0.0~ Hz
0.0~ Hz
0.1~6000 sec.
0.1~6000 sec.
0.0~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
0:Forward run
1:Reverse run
2:Forward run (Forward/reverse switchable on operation
panel)
3:Reverse run (Forward/reverse switchable on
operation panel)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
Default
Write during
setting unit
Speed
setting
running
(Panel/Communi
control
cation)
-/-
-/-
●/-
●/-
1/1
0
Disabled
●/-
-/-
-/-
-/●
-/●
0.1/0.1
*1
Enabled
-
0.1/0.01
*3
Disabled
●/●
1/0.1
*1
Disabled
●/●
0.1/0.01
80.0
Disabled
●/●
0.1/0.01
*3
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.1 *2
*1
Enabled
●/●
0.1/0.1 *2
*1
Enabled
●/●
0.1/0.01
*3
Enabled
●/●
0.1/0.01
*3
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
1/1
0
Enabled
●/●
PM
V/f
Reference
Torque
control
control
-/-
-
-/-
-
-/-
-
-
-/-
-
-
●/-
-
-
5. 6
-/-
-
-/-
-
-/-
-
-
-/●
-
-
-
5. 7
●/●
5. 8
●/●
5. 8
●/●
5. 9
-
5. 10
-
5. 10
-
5. 2
-
5. 2
-
5. 11
-
5. 11
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
●/●
5. 13