[28] Operation panel parameters [1/3]
Communi
Title
cation
Function
No.
Parameter write protect

0700
selection
0701
Current/voltage unit selection

Frequency free unit display

0702
magnification
Frequency free unit conversion

0703
selection
Free unit display gradient
0705

characteristic
0706
Free unit display bias


0707
Changing step selection 1

0708
Changing step selection 2

0709
Standard monitor hold function
Standard monitor display
0710

selection
Status monitor 1 display

0711
selection
Status monitor 2 display

0712
selection
Status monitor 3 display
0713

selection
Status monitor 4 display
0714

selection
Status monitor 5 display

0715
selection
Status monitor 6 display

0716
selection
Status monitor 7 display
0717

selection
Status monitor 8 display
0718

selection
Operation command clear

0719
selection when standby terminal
(ST) is OFF
Operation panel stop pattern

0721
selection
Operation panel torque
0725

command
Operation panel tension torque
0727

bias
Operation panel load sharing

0728
gain
Operation panel override

0729
multiplication gain
This parameter moves to a fundamental parameter. *1:  For the adjustment range, see the table on page K-40.
Adjustment range
0:Permit
1:Prohibit
0:%, 1:A (ampere)/V (volt)
0.00:OFF, 0.01~200.0
0:All frequencies display free unit conversion
1:PID frequencies free unit conversion
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
0.00~ Hz
0.00:Disabled, 0.01~ Hz
0:Disabled, 1~255
0:Real time, 1:Peak hold, 2:Minimum hold
0~80 *1
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
0:Clear operation command
1:Retain operation command
0:Deceleration stop
1:Coast stop
-250~250%
-250~250%
0~250%
-100~100%
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
1/1
0
Enabled
●/●
1/1
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
1
Enabled
●/●
1/1
2
Enabled
●/●
1/1
3
Enabled
●/●
1/1
4
Enabled
●/●
1/1
8
Enabled
●/●
1/1
16
Enabled
●/●
1/1
15
Enabled
●/●
1/1
14
Enabled
●/●
1/1
1
Enabled
●/●
1/1
0
Enabled
●/●
1/0.01
0
Enabled
-
1/0.01
0
Enabled
-
1/0.01
100
Enabled
-
1/0.01
0
Enabled
●/●
PM
Torque
V/f Constant Reference
control
control
●/●
6. 36. 1
●/●
5. 15
●/●
6. 36. 2
●/●
6. 36. 2
●/●
6. 36. 2
●/●
6. 36. 2
●/●
6. 36. 3
●/●
6. 36. 3
●/●
8. 3
●/●
8. 3
●/●
8. 3
●/●
8. 3
●/●
8. 3
●/●
8. 3
●/●
8. 3
●/●
8. 3
●/●
8. 3
●/●
8. 3
●/●
6. 36. 5
●/●
6. 36. 6
●/●
-
-
6. 36. 7
●/●
-
-
6. 36. 8
●/●
-
-
6. 36. 8
-
6. 34