Toshiba Tosvert VF-AS1 Instruction Manual page 295

The new high-performance inverter
Hide thumbs Also See for Tosvert VF-AS1:
Table of Contents

Advertisement

[30] My function [1/5]
Communi
Title
cation
Function
No.
0900
Input function target 11

*1:  For details, refer to Instruction Manual (E6581335) specified in Section 6.42.
Adjustment range
Input terminal function number
0:Deselect
1:F terminal
2:R terminal
3:-
4:RES terminal
5:S1 terminal
6:S2 terminal
7:S3 terminal
8:RR/S4 terminal
9:LI1 terminal
10:LI2 terminal
11:LI3 terminal
12:LI4 terminal
13:LI5 terminal
14:LI6 terminal
15:LI7 terminal
16:LI8 terminal
17:B12 terminal
18:B13 terminal
19:B14 terminal
20:B15 terminal
21:Virtual input terminal 1
22:Virtual input terminal 2
23:Virtual input terminal 3
24:Virtual input terminal 4
25~32:Internal terminal 1~8
918~934:MY function number
1000~1255:Output selection number
2000~2099:FD00~FD99
3000~3099:FE00~FE99
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
1/1
0
Disabled
●/●
PM
V/f Constant Reference
Torque
control
control
●/●
*1