Toshiba Tosvert VF-AS1 Instruction Manual page 255

The new high-performance inverter
Hide thumbs Also See for Tosvert VF-AS1:
Table of Contents

Advertisement

Selection table of separate-type options (2/2)
Appli-cable
Voltage
Inverter
motor
class
model
[kW]
0.4
VFAS1-2004PL
0.75
VFAS1-2007PL
1.5
VFAS1-2015PL
2.2
VFAS1-2022PL
3.7/4.0
VFAS1-2037PL
5.5
VFAS1-2055PL
7.5
VFAS1-2075PL
11
VFAS1-2110PM
200V
15
VFAS1-2150PM
class
18.5
VFAS1-2185PM
22
VFAS1-2220PM
30
VFAS1-2300PM
37
VFAS1-2370PM
45
VFAS1-2450PM
55
VFAS1-2550P
75
VFAS1-2750P
0.75
VFAS1-4007PL
1.5
VFAS1-4015PL
2.2
VFAS1-4022PL
3.7/4.0
VFAS1-4037PL
5.5
VFAS1-4055PL
7.5
VFAS1-4075PL
11
VFAS1-4110PL
15
VFAS1-4150PL
18.5
VFAS1-4185PL
22
VFAS1-4220PL
30
VFAS1-4300PL
37
VFAS1-4370PL
45
VFAS1-4450PL
55
VFAS1-4550PL
75
VFAS1-4750PL
90
VFAS1-4900PC
110
VFAS1-4110KPC
400V
class
132
VFAS1-4132KPC
160
VFAS1-4160KPC
200
VFAS1-4200KPC
220
VFAS1-4220KPC
280
VFAS1-4280KPC
355
VFAS1-4355KPC
400
VFAS1-4400KPC
500
VFAS1-4500KPC
(*1): Model in square brackets is fitted with top cover.
(*2): To use a 400V/200kW inverter or larger in combination with an external braking resistor (DGP600 series), a braking unit (PB7) with a built-in braking
resistor drive circuit is also needed.
(*3): The options are selected based on the premise that 600V HIV insulated wires (continuous allowable temperature: 75°C) are used.
(*4): Each MSF-****Z model is composed of a reactor, a resistor and a capacitor, and as a guide, use a cable 300m or less in length to connect the
inverter to the motor.
Each MSL-****T model is an output-dedicated surge suppression reactor, and as a guide, use a cable 100m or less in length (or 50m or less for a
shielded cable) to connect the inverter to the motor, although allowable cable lengths vary according to the input voltage.)
(*5): Be sure to connect DC reactor to 200V-55kW and above models and 400V-90kW and above models. (Not necessary for DC power input.)
When a 200V-55kW and above models or 400V-90 to 280kW models is replaced with new one, the reactor (model: DCL-****) used with the current
inverter can be used as-is with the new inverter. In such cases, therefore, you do not need to purchase any reactors in this table.
DC reactor
Input AC reactor
(DCL)
(ACL)
(*5)
DCL2-2004
PFL-2005S
DCL2-2007
DCL2-2015
PFL-2011S
DCL2-2022
PFL-2018S
DCL2-2037
PFL-2025S
DCL2-2055
DCL2-2075
PFL-2050S
PFL-2100S
Built-in
PFL-2150S
PFL-2200S
PFL-2300S
Attached as standard
PFL-2400S
DCL2-4007
DCL2-4015
PFL-4012S
DCL2-4022
DCL2-4037
DCL2-4055
PFL-4025S
DCL2-4075
DCL2-4110
DCL2-4150
PFL-4050S
PFL-4100S
Built-in
PFL-4150S
PFL-4300S
PFL-4400S
PFL-4600S
PFL-4800S
Attached as standard
PFL-4450S
×2(parallel)
PFL-4613S
×2(parallel)
J-7
Motor end
Braking resistor
surge voltage
(*1)
suppression
filter (*4)
PBR-2007
PBR-2002
PBR-2037
PBR3-2055
PBR3-2075
PBR3-2110
PBR3-2150
PBR3-2220
PBR-222W002
DGP600W-B1
[DGP600W-C1]
MSF-4015Z
PBR-2007
MSF-4037Z
PBR-4037
PBR3-4055
MSF-4075Z
PBR3-4075
PBR3-4110
MSF-4150Z
PBR3-4150
MSF-4220Z
PBR3-4220
MSF-4370Z
PBR-417W008
MSF-4550Z
MSF-4750Z
MSL-4215T
MSL-4314T
DGP600W-B2
[DGP600W-C2]
MSL-4481T
PB7-4200K(*2)
DGP600W-B3
[DGP600W-C3]
PB7-4200K(*2)
DGP600W-B4
[DGP600W-C4]
MSL-4759T
PB7-4400K(*2)
DGP600W-B3
×2(parallel)
[DGP600W-C3
×2(parallel)]
PB7-4400K(*2)
MSL-41188T
DGP600W-B4
×2(parallel)
[DGP600W-C4
×2(parallel)]
E6581442
Control
power
supply
backup
CPS002Z
10