[12] Tripless intensification setup [2/2]
Communi
Title
cation
Function
No.
Base frequency voltage
0307
selection
(correction of supply voltage)
0308
Dynamic braking resistance
0309
Allowable continuous braking resistance 0.01~600.0kW
Non-stop control time/deceleration
0310
time during power failure
Reverse-run prohibition
0311
selection
0312
Random mode
Output voltage waveform
0313
selection *4
Carrier frequency control mode
0316
selection
Synchronized deceleration time
0317
(time elapsed between start of
deceleration to stop)
Synchronized acceleration time
(time elapsed between start of
0318
acceleration to achievement of
specified speed)
Regenerative over-excitation
0319
upper limit
This parameter moves to a fundamental parameter. *1: Default values vary depending on the capacity. See the table of K-48.
*2: Changing the parameter enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).
*3: Although the setting can be written into memory if is set to (power ride-through control), it cannot be written if is set to (deceleration stop during a power failure).
*4: is available for VFAS1-2550P, VFAS1-4900PC and above.
[13] Drooping control
Communi
Title
cation
Function
No.
Drooping gain
0320
0321
Speed at drooping gain 0%
0322
Speed at drooping gain 0.0~320.0Hz (Enabled if =3, 4, 7 or 8)
0323
Drooping insensitive torque
*1: Drooping gain can be changed within a range of 0.1 to 100.0% during operation. When changing the setting to 0.0 (no drooping) or 0.0, stop operation.
Adjustment range
0:Without voltage compensation (limitless output voltage)
1:With voltage compensation (limitless output voltage)
2:Without voltage compensation (limited output voltage)
3:With voltage compensation (limited output voltage)
0.5~1000Ω
0.1~320.0 sec.
0:Permit all, 1:Prohibit reverse run
2:Prohibit forward run
0:Disabled, 1:Enabled
0:PWM carrier frequency control 1
1:PWM carrier frequency control 2
0:Not decrease carrier frequency automatically
1:Decrease carrier frequency automatically
2:Not decrease carrier frequency automatically,
400V class supported
3:Decrease carrier frequency automatically, 400V
class supported
4:Not decrease carrier frequency automatically,
with sinusoidal filter
5:Decrease carrier frequency automatically, with
sinusoidal filter
0.1~6000 sec.
0.1~6000 sec.
100~160%
Adjustment range
0.0~100.0% (Enabled if =3, 4, 7 or 8)
0.0~320.0Hz (Enabled if =3, 4, 7 or 8)
0~100% (Enabled if =3, 4, 7 or 8)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
Parameter is changeable, but fixed to
"with voltage compensation" internally.
When is set to 0 or 1, fixed at
1/1
0
Disabled
1 internally.
When is set to 2 or 3, fixed at
3 internally.
0.1/0.1
*1
Disabled
●/●
0.01/0.01
*1
Disabled
●/●
Enabled *3/
0.1/0.1
2.0
●/●
Disabled
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
1
Disabled
●/●
0.1/0.1 *2
2.0
Enabled
●/●
0.1/0.1 *2
2.0
Enabled
●/●
1/1
140
Disabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
0.1/0.1
0.0
Enabled *1
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
1/1
10
Enabled
●/●
PM
V/f
Reference
Torque
control
control
●
6. 14. 3
●/●
●
●
5. 19
●/●
●
●
5. 19
-/-
●
●
5. 18. 2
●/●
●
●
6. 14. 4
●/●
●
●
5. 17
●/●
●
●
6. 14. 5
●/●
●
●
5. 17
-/-
●
●
5. 18. 2
-/-
●
●
5. 18. 2
●/●
-
●
6. 14. 2
PM
Torque
V/f
Reference
control
control
-
-
-
6. 15
-
-
-
6. 15
-
-
-
6. 15
-
-
-
6. 15