Toshiba Tosvert VF-AS1 Instruction Manual page 286

The new high-performance inverter
Hide thumbs Also See for Tosvert VF-AS1:
Table of Contents

Advertisement

[26] Override
Communi
Title
cation
Function
No.

0660
Override addition input selection
Override multiplication input

0661
selection
Logic output/pulse output

0669
selection (OUT1)

0670
AM terminal meter selection
This parameter moves to a fundamental parameter.
*1:  For the adjustment range, see the table on page K-40.
[27] Meter output [1/2]
Communi
cation
Function
Title
No.

0671
AM terminal meter adjustment

0672
MON1 terminal meter selection
MON1 terminal meter

0673
adjustment

0674
MON2 terminal meter selection
MON2 terminal meter

0675
adjustment

0676
Pulse output function selection

0677
Selection of number of pulses

0678
Constant at the time of filtering
FM voltage/current output

0681
switching
FM output gradient

0682
characteristic

0683
FM bias adjustment
This parameter moves to a fundamental parameter.
*1:  For the adjustment range, see the table on page K-40.
*2:  For details, refer to Instruction Manual (E6581341) specified in Section 6.42.
Adjustment range
0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:Operation panel input enabled (including
LED/LCD option input)
5:2-wire RS485 input enabled
6:4-wire RS485 input enabled
7:Communications option input enabled
8:Optional AI1 (differential current input)
9:Optional AI2 (voltage/current input)
10:UP/DOWN frequency
11:Optional RP pulse input
12:Optional high-speed pulse input
13:-
0:Disabled, 1:VI/II, 2:RR/S4, 3:RX, 4:,
5:Optional AI1
0:Logic output
1:Pulse output
0~64 *1
Adjustment range
-
0~76 *1
-
0~76 *1
-
0~49 *1
1.00~43.20kHz
4msec, 8msec~100msec
0:Voltage 0~10V output
1:Current 0~20mA output
0:Negative gradient (descending)
1:Positive gradient (ascending)
-10.0~100.0%
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Disabled
●/●
1/1
2
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
-
Enabled
●/●
1/1
4
Enabled
●/●
1/1
-
Enabled
●/●
1/1
5
Enabled
●/●
1/1
-
Enabled
●/●
1/1
0
Enabled
●/●
0.01/0.01
3.84
Enabled
●/●
1/1
64
Enabled
●/●
1/1
0
Disabled
●/●
1/1
1
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
PM
Torque
V/f Constant Reference
control
control
-
6. 34
-
6. 34
●/●
6. 35. 1
●/●
5. 16
PM
V/f Constant Reference
Torque
control
control
●/●
5. 16
●/●
*2
●/●
*2
●/●
*2
●/●
*2
●/●
6. 35. 1
●/●
6. 35. 1
●/●
5. 16
●/●
6. 35. 3
●/●
6. 35. 3
●/●
6. 35. 3

Advertisement

Table of Contents
loading

Table of Contents