[26] Override
Communi
Title
cation
Function
No.
0660
Override addition input selection
Override multiplication input
0661
selection
Logic output/pulse output
0669
selection (OUT1)
0670
AM terminal meter selection
This parameter moves to a fundamental parameter.
*1: For the adjustment range, see the table on page K-40.
[27] Meter output [1/2]
Communi
cation
Function
Title
No.
0671
AM terminal meter adjustment
0672
MON1 terminal meter selection
MON1 terminal meter
0673
adjustment
0674
MON2 terminal meter selection
MON2 terminal meter
0675
adjustment
0676
Pulse output function selection
0677
Selection of number of pulses
0678
Constant at the time of filtering
FM voltage/current output
0681
switching
FM output gradient
0682
characteristic
0683
FM bias adjustment
This parameter moves to a fundamental parameter.
*1: For the adjustment range, see the table on page K-40.
*2: For details, refer to Instruction Manual (E6581341) specified in Section 6.42.
Adjustment range
0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:Operation panel input enabled (including
LED/LCD option input)
5:2-wire RS485 input enabled
6:4-wire RS485 input enabled
7:Communications option input enabled
8:Optional AI1 (differential current input)
9:Optional AI2 (voltage/current input)
10:UP/DOWN frequency
11:Optional RP pulse input
12:Optional high-speed pulse input
13:-
0:Disabled, 1:VI/II, 2:RR/S4, 3:RX, 4:,
5:Optional AI1
0:Logic output
1:Pulse output
0~64 *1
Adjustment range
-
0~76 *1
-
0~76 *1
-
0~49 *1
1.00~43.20kHz
4msec, 8msec~100msec
0:Voltage 0~10V output
1:Current 0~20mA output
0:Negative gradient (descending)
1:Positive gradient (ascending)
-10.0~100.0%
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Disabled
●/●
1/1
2
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
-
Enabled
●/●
1/1
4
Enabled
●/●
1/1
-
Enabled
●/●
1/1
5
Enabled
●/●
1/1
-
Enabled
●/●
1/1
0
Enabled
●/●
0.01/0.01
3.84
Enabled
●/●
1/1
64
Enabled
●/●
1/1
0
Disabled
●/●
1/1
1
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
PM
Torque
V/f Constant Reference
control
control
-
●
●
6. 34
-
●
●
6. 34
●/●
●
●
6. 35. 1
●/●
●
●
5. 16
PM
V/f Constant Reference
Torque
control
control
●/●
●
●
5. 16
●/●
●
●
*2
●/●
●
●
*2
●/●
●
●
*2
●/●
●
●
*2
●/●
●
●
6. 35. 1
●/●
●
●
6. 35. 1
●/●
●
●
5. 16
●/●
●
●
6. 35. 3
●/●
●
●
6. 35. 3
●/●
●
●
6. 35. 3