Toshiba Tosvert VF-AS1 Instruction Manual page 282

The new high-performance inverter
Hide thumbs Also See for Tosvert VF-AS1:
Table of Contents

Advertisement

[23] Pattern operation [2/3]
Communi
Title
cation
Function
No.

0537
Pattern group 2 selection 6

0538
Pattern group 2 selection 7

0539
Pattern group 2 selection 8

0540
Speed 1 operation time

0541
Speed 2 operation time

0542
Speed 3 operation time
0543
Speed 4 operation time

0544
Speed 5 operation time

0545
Speed 6 operation time

0546
Speed 7 operation time

0547
Speed 8 operation time

0548
Speed 9 operation time


0549
Speed 10 operation time

0550
Speed 11 operation time

0551
Speed 12 operation time

0552
Speed 13 operation time

0553
Speed 14 operation time

0554
Speed 15 operation time
Preset speed operation mode

0560
selection
Preset speed operation

0561
frequency 1 operation mode
Preset speed operation
0562

frequency 2 operation mode
Preset speed operation

0563
frequency 3 operation mode
Preset speed operation

0564
frequency 4 operation mode
Preset speed operation

0565
frequency 5 operation mode
Preset speed operation

0566
frequency 6 operation mode
Preset speed operation

0567
frequency 7 operation mode
Preset speed operation

0568
frequency 8 operation mode
Preset speed operation

0569
frequency 9 operation mode
Adjustment range
0:Skip, 1~15
0:Skip, 1~15
0:Skip, 1~15
0.1~6000 (The unit depends on the setting of
.)
6000:Infinite (depends on the stop trigger entered)
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
0:Preset speed operation with no mode
1:Preset speed operation with mode
0:Forward run
+1:Reverse run
+2:Acceleration/deceleration switching signal 1
+4:Acceleration/deceleration switching signal 2
+8:V/f switching signal 1
+16:V/f switching signal 2
+32:Torque limit switching signal 1
+64:Torque limit switching signal 2
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
0.1/0.1
5.0
Enabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
PM
Torque
V/f Constant Reference
control
control
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
6. 31
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12