Code
Category
Error Name
14C0
DAMPER KIT
DAMPER KIT error
PG position
150C
PG
undetectable error
1519
APG
Oscillation error
151A
APG
Overload error
151B
APG
Over speed error
APG
Reversing error
151C
151D
APG
Driving time-out error
TROUBLE SHOOTING
Table 2-2. Service Call Error
Cause
The DAMPER KIT has reached its end of specified
life.
When changing the PG, the PG SENSOR could not
detect the PG position.
The control terminal (Vre terminal) of the APG
motor driver has shorted out.
Connection failure of the APG motor.
Overcurrent to the APG motor was detected.
APG motor cable is damaged.
Irregular load
APG encoder failure
APG motor failure
The APG motor was driven at a speed faster than a
predetermined one during deceleration.
Irregular load
APG encoder failure
APG motor driver failure
The number of occurrences of reversing the APG
motor has reached a predetermined limit.
The polarity of APG motor cable is opposite.
APG motor failure
Detects that the driving period is irregularly long.
Irregular load
Firmware becomes out of control.
Remedies for Service Call Error
Check Item
---
1. Is the PG SENSOR out of order? Does the light
shielding plate react to the sensor?
2. Do the planetary gearing work normally? (Do the
planet gears and outer gears properly engage with
each other?)
3. Is the CR UNIT out of its home position? (Do the
planet gears and outer gears properly engage with
each other?)
1. Is the APG motor driver on the MAIN BOARD
damaged?
2. Is there any foreign materials around the APG
motor driver?
Is there any problems such as damaged cable in the
connections below?
APG motor (APG encoder) to MAIN BOARD
(CN15)
---
Is there any problems such as damaged cable in the
connections below?
APG motor (APG encoder) to MAIN BOARD
(CN15)
---
Revision B
Remedy
Replace the DAMPER KIT
(See
P.123)
and reset its counter
(See
P.231).
1. Replace the PG SENSOR.
(See
P.146)
2. Replace the APG UNIT.
(See
P.144)
3. Remove any obstacles around
the CR UNIT home position.
The printer changes the PG with
the CR UNIT being at its home
position.
1. Remove the foreign material.
2. If the error still occurs, replace
the MAIN BOARD.
(See
P.111)
Replace the APG UNIT.
(See
P.144)
1. Replace APG UNIT.
(See
P.144)
2. Replace the MAIN BOARD.
(See P.111)
Replace APG UNIT.
(See P.144)
Replace the MAIN BOARD.
(See
P.111)