Club Car 2008-2011 Maintenance And Service Manual page 278

Domestic powerdrive, iq plus and high frequency battery chargers
Table of Contents

Advertisement

10
HIGH FREQUENCY CHARGER (ONBOARD)
Figure 10-4 Hydrometer Test
View at eye level.
Interpreting the Results of the Hydrometer Test: 12-Volt Batteries
The approximate state of charge can be determined from the following table:
SPECIFIC GRAVITY
(TEMPERATURE
CORRECTED)
1.250-1.280
1.220-1.240
1.190-1.210
1.160-1.180
If the difference between the cells is 0.020 or more, the low cell should be suspected. It may require a catch-
up charge or it may be a weak cell. When the variations between cells reach 0.050 or more, the battery with
the low cell should be replaced.
VEHICLE
BATTERY
NO.
NO.
12
1
54
3
38
2
22
4
Page 10-12
2008-2011 Domestic Battery Charger Maintenance and Service Manual
1.250
1.280
APPROXIMATE
STATE OF CHARGE
100%
75%
50%
25%
ELECTROLYTE
CORRECTION
TEMPERATURE
FACTOR
CELL 1
1.275 –
20 °F
–0.024
0.024 =
(–6.6 °C)
1.260 –
50 °F
–0.012
0.012 =
(10 °C)
1.200 +
100 °F
+.008
0.008 =
(37.8 °C)
1.240 –
80 °F
.000
(26.7 °C)
= 1.240
CORRECTED SPECIFIC GRAVITY
CELL 2
CELL 3
CELL 4
1.280 –
1.280 –
1.275 –
0.024 =
0.024 =
0.024 =
1.251
1.256
1.256
1.200 –
1.270 –
1.265 –
0.012 =
0.012 =
0.012 =
1.248
1.188
1.258
1.180 +
1.170 +
1.200 +
0.008 =
0.008 =
0.008 =
1.208
1.188
1.178
Float
1.235 –
1.245 –
0
0
does
= 1.245
not rise
= 1.235
CELL 5
CELL 6
1.280 –
1.280 –
Sound Battery – Fully
0.024 =
0.024 =
1.251
1.256
1.256
1.270 –
1.260 –
0.012 =
0.012 =
1.253
1.258
1.248
1.180 +
1.198 +
0.008 =
0.008 =
1.208
1.188
1.198
1.250 –
1.240 –
0
0
0
= 1.250
= 1.240
Test Procedures
REQUIRED
ACTION
Charged
Bad no. 2 Cell
Discharged
Battery –
Recharge and
Recheck
no.3 Cell Dead
– Replace Battery

Hide quick links: