POWERDRIVE 2 CHARGER (EXTERNAL)
COMPUTER
Figure 5-3 Charge Circuit and Battery Configuration – Precedent Vehicles

CHARGER INSTALLATION AND OPERATION

See General Warning, Section 1, Page 1-1. See additional WARNING on page 5-1.
ý
DANGER
• The charging area must be ventilated. Hydrogen level in the air must never exceed 2%. The
total volume of air in the charging area must be changed five times per hour. Exhaust fans
should be located at the highest point of the roof. Contact a local HVAC engineer.
• Do not charge the vehicle batteries with the vehicle covered or enclosed. Any enclosure or
cover should be removed or unzipped and pulled back when batteries are being charged. An
accumulation of hydrogen gas could result in an explosion.