7. Testing the system

Periodic test

The components of your security system are designed to be maintenance-free as much as possible.
Nevertheless, it is mandatory to test the system at least once a week and after an alarm event to verify that all
system sirens, detectors, keyfobs, keypads and other peripherals function properly. Proceed as described in this
section and if there is any problem, notify your installer at once.
The test is performed in four parts:
Siren Test: Each siren of the system is automatically activated for 3 seconds (outdoor sirens with low volume).
In addition, the system tests the siren of enrolled smoke sensors.
Temp/Light Test: For devices with temperature sensing, the panel displays the temperature of each zone in
Celsius or Fahrenheit. For devices that have both temperature and light sensing, the panel displays the
temperature and light intensity of each zone.
Other Device Test: Each of the other devices in the system is activated by the user and the display indicates
which devices were not yet tested. The "it's me" indication helps to identify the untested devices if necessary.
A counter also indicates the number of devices that remain untested.
Email Test: Generates an event to be sent to the predefined private email addresses (see Chapter 4,
section B.12)
Carefully read the section titled "Additional Information" according to the indicated references
see table at end of this section.
A. To enter the periodic test menu
1.
READY 00:00
PERIODIC TEST
2.
ENTER CODE: 
CODE
3.
Go to step 4
B. To test the sirens
4.
SIRENS TEST
5.
SIREN N
6.
SIRENS TESTS END
or
D-307082 PowerMaster 360 User's Guide
Make sure the system is disarmed and then press the
repeatedly until the display reads "PERIODIC TEST" and press
The screen will now prompt you to enter your user code.
Enter your User Code.
The display now reads [SIRENS TEST].
To initiate the siren test press
all 5 LEDs on the panel should light (LED test).
The display now reads [SIREN N], where "N" indicates the zone location
assigned to the siren that is currently being tested.
The first siren enrolled in the panel sounds for 3 seconds after which the
PowerMaster-360 system will automatically repeat the procedure for the next
siren enrolled in the system until all sirens are tested.
You should listen to the sirens sounds and make sure that all sirens sound.
Once all the sirens have been tested, the control panel will now test the
sirens of smoke sensors that are enrolled in the alarm system. The display
now reads [Zxx: SMOKE SIREN], where "Zxx" indicates the zone number of
the smoke sensor, and alternates with [<OK> TO CONTINUE]. During this
time, the siren of the tested smoke sensor will sound for up to one minute.
Press
to test the siren of the next smoke sensor.
When all the sirens test is complete, the display reads [SIREN TESTS END].
Press the
or the
the next step for zone temperature display.