Starting The Camera With The Factory Ip Address - Mobotix D24M Manual

Camera
Table of Contents

Advertisement

116
/146
D24 User Manual: OPERATInG THE CAMERA

3.2.6 Starting The Camera With The Factory IP Address

Under certain circumstances, you may have to reset the camera to its factory IP address.
This could be the case, for example, if the IP address has been lost or the camera does
not respond to the last known IP address.
1. If the camera is running, disconnect the camera's power supply.
2. Reconnect the power supply of the camera.
3. Wait until both LEDs light up simultaneously for the first time.
4. Press the camera's L key within four seconds.
Press the „L" key
5. After about two more seconds, the camera is accessible via its factory IP address
(see label on the camera housing).
If you use the camera's L key to load the factory network configuration, this configura-
tion is not automatically saved in the camera's Flash memory. When the camera is
next rebooted without using L key, the last stored network configuration will be used.
To permanently store the new network configuration in the camera's Flash memory,
open Admin Menu > Store.
As opposed to resetting the camera using Admin Menu > Reset configuration to
factory defaults, the user information will not be reset if the camera is booted using
the factory IP address.
© MOBOTIX AG • Security-Vision-Systems • Made in Germany