Chapter 8 Operation and Maintenance
iRMC Controller Error
Patch for installed CPU not loaded. Please
run the bios flash update diskette.
PCI system error BUS/DEVICE/FUNCTON
xxxxh
CPU had been changed
Power supply status is warning
Power supply status is critical
Power unit status is warning
Power unit status is critical
Memory module error
No usable CPU
No usable system memory
Application CPU timeout error
PCI Express link width degraded
196
table: List of POST error messages
Message
Description
It indicates a Server Management Controller error. Turn off the
server and turn it back on. If the message still appears, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
Microcode update, which is necessary for the installed processor, is
not included in BIOS. Check whether proper CPUs are installed, and
update BIOS by using BIOS update tool supplied with CPUs. If the
message still appears after the update, start up BIOS Setup Utility,
and change the setting as follows. Select the [Server] menu – the
[CPU Status] submenu – [Re-enable Failed CPUs], and change it to
"Yes". If the message still appears thereafter, the baseboard must be
replaced. Contact an office listed in the "Contact Information" of
"Start Guide".
It indicates a PCI error. The baseboard or CPUs must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
CPUs have been changed.
If the message appears after the baseboard or CPUs are replaced,
start up BIOS Setup Utility, and select the [Exit] menu – [Save
Changes & Exit]. If the message still appears, the CPUs or the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
It indicates a redundant PSU error. The message may appear if a
pair to PSU is damaged when you operate with redundant
configurations. Replace PSU and Power BP in this order.
It indicates a memory module error. Check whether the memory
modules are properly installed. If the message appears although
the installation is proper, replace the memory modules.
It indicates a CPU error. No CPUs are available for the system.
Replace the CPUs. If the message still appears, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
It indicates a memory error. No memory modules are available for
the system. Replace the memory modules. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of "Start Guide".
It indicates a CPU error. Turn off the server and turn it back on. If
the message still appears, check the error log and replace the
relevant CPU. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information" of
"Start Guide".
It indicates a PCI Express card error. Check whether the PCI
Express cards are properly installed. If the message appears
although the installation is proper, replace the PCI Express cards.
If the message still appears after the replacement, the baseboard
or CPUs must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".