Event logs

When configuring a Team, the following event logs will be generated (source: iANSMiniport).
ID
Type
3
Error
The necessary registry parameter could not be read.
To resolve this problem, delete the adapter team, and
create a new team.
6
Information
The primary adapter has been initialized: (Adapter
name)
7
Information
The adapter has been initialized: (Adapter name)
8
Information
(Team name): The team has been initialized.
10
Information
The current primary adapter is changed from the next
adapter: (Adapter name)
11
Warning
The next adapter link is not connected: (Adapter
name)
12
Information
The secondary adapter has a priority: (Adapter name)
13
Warning
(Adapter name) has been disabled with a team.
14
Information
The secondary adapter has been added to a team
again: (Adapter name)
15
Information
The next adapter link is connected: (Adapter name)
16
Warning
(Team name): The last adapter has been unlinked.
Network connection has failed.
17
Information
(Team name): The adapter has established a link
again. The network connection has been recovered.
18
Information
The primary adapter at the next priority level has been
detected: (Adapter name)
19
Information
The secondary adapter at the next priority level has
been detected: (Adapter name)
20
Information
The primary adapter at the next priority level is
preferentially handled: (Adapter name)
21
Information
The secondary adapter at the next priority level is
preferentially handled: (Adapter name)
22
Warning
The primary adapter could not detect the next probe:
(Adapter name) Cause: The team may be divided into
groups.
35
Warning
(Team name) without one adapter is initialized.
Confirm that all adapters exist and function.
38
Information
(Adapter name) has been deleted from the team.
42
(Adapter name) is not specified properly. The adapter
Warning
cannot process the remote management function while
being a network team.
table: Event logs
Message
PRIMERGY RX600 S4 User's Guide
Remarks
Even if a team is created successfully,
this error log may be stored during a
system startup. Ignore the log since
there is no problem.
Even if a team is created successfully,
these logs are stored during a system
startup. Ignore the logs since there is
no problem.
After a team is configured, these logs
may be stored many times in the
system log on the Event Viewer
during a system startup. Ignore the
logs since there is no problem.
The logs may not be stored when
[Link Standby] is enabled in
[Advanced Settings] of the LAN
adapter.
This log may be stored even if the
remote management function is not
used on the onboard LAN. When not
using the remote management
function, ignore the log since there is
no problem.