Sun Microsystems Sun Ultra 60 Service Manual page 165

Hide thumbs Also See for Sun Ultra 60:
Table of Contents

Advertisement

Figure B–2
Serial Port A and B Connector Pin Configuration
Serial Port A and B Connector Pin Assignments
TABLE B–2
Pin
Mnemonic
1
2
TXD
3
RXD
4
RTS
Signal Name
Not connected
Transmit Data
Receive Data
Ready To Send
Description
None
Used by the data terminal
equipment (DTE) to transmit
data to the data circuit
equipment (DCE). Except
when control data is being
sent, RTS, CTS, and DCD
must be ON for this line to
be active.
Used by the DCE in
response to received data
from the DTE.
Used by the DTE to
condition the DCE for data
transmission. The transition
to ON directs the DCE to go
into transmit mode. The
transition to OFF directs the
DCE to complete the
transmission.
Signal Descriptions