ADSP-219x DSP Loader Guide
This section provides reference information about the loader's command
line interface. A list of the command-line switches appears in
page
3-21.
When using the loader within VisualDSP++, settings on the Load page of
the Project Options dialog box correspond to the loader's command-line
switches. For more information, see the VisualDSP++ 3.5 User's Guide for
16-Bit Processors or online Help.
ADSP-219x Loader Command-Line Reference
Use the following syntax for the loader's command line.
elfloader sourcefile [outputfile] -proc processor [-switch ...]
where:
•
sourcefile
into a single-processor boot-loadable file. A file name can include
the drive and directory. Enclose long file names within
straight-quotes,
•
outputfile
extension. Each run generates a single output file.
.LDR
•
-proc processor
loader file is to be built. Provide a part number for every input
if designing multi-processor systems. Running the loader without
results in an error.
-proc
•
-switch ...
select operations and modes for the loader. See
page 3-20
VisualDSP++ Loader Manual
for 16-Bit Processors
—Identifies the executable file (
"long file name"
—Optional name of the loader's output, a file with the
—Part number of the processor for which the
—One or more optional switches to process. Switches
for a complete list of the loader command-line switches.
ADSP-219x DSP Loader/Splitter
.DXE
.
Table 3-5 on
Table 3-6 on
) to be processed
.DXE
3-19
Need help?
Do you have a question about the VisualDSP++ 3.5 and is the answer not in the manual?
Questions and answers