Freeze temp (06107 to 06607)
Default setting is 42°F.
This setting determines the temperature point the EnergySaver module detects a potential freeze (heating
failure) condition. The adjustable range is from 40 to 90°F.
Note:
This is the same menu found under
To set the Freeze temp, do the following:
1. With the desired partition selected, press A or B until the display shows FREEZE TEMP (current
setting). Enter the desired temperature (40 to 90°F).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Alarm verify (06108 to 06608)
Default setting is Off.
This setting determines whether the panel reports to the central monitoring station after a single sensor or zone
trip (off) or waits for a second trip before reporting (on).
This setting affects sensors/zones in groups 10 through 20. If Alarm verify is on, group 18 responds the same as
group 17 (See Appendix A,
Note:
For UL listed installations, Alarm verify must be off.
To turn the setting off or on, do the following:
1. With the display showing ALARM VERIFY OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
System tamper (06109 to 06609)
Default setting is Off.
This setting determines how the panel handles possible tamper situations. When this feature is on, the panel
reacts as follows:
•
Initiates an alarm when the system prompts for an access code (arming/disarming, etc.) and several
wrong access codes are entered (40 consecutive invalid keypresses).
•
Reports to the central station if a bus device stops communicating with the panel.
•
Reports to the central monitoring station if a tamper condition occurs on unarmed RF (wireless)
devices.
Note:
For UL commercial listed installations (UL 1610), System tamper must be on.
To turn the setting off or on, do the following:
1. With the display showing SYSTEM TAMPER OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Accessory modules - bus devices settings
System planning
sheets).
on page 93.
Chapter 3
81
Programming