112
Concord 4
Installation Manual
Outputs (065xnn where nn is schedule number and x is output number minus 1)
Default setting is Off.
This setting lets you attach outputs to a time schedule. Onboard outputs are 1 to 2, SnapCard outputs are 3 to 6.
Note:
Only onboard and SnapCard outputs can be scheduled. These outputs can only be scheduled if output text has been
entered in installer programming and if the output is assigned to the same partition as the touchpad used.
To attach schedules to outputs, do the following:
1. Press A or B until the display shows ATTACH SCHEDULES TO EVENTS.
2. Press # then A or B until the display shows OUTPUTS. Press # to enter the Outputs menu.
3. Press A or B until the output appears.
4. Press # and the display shows SCHEDULE 00 OFF/ON (current setting). If you want a different
schedule, press A or B until the schedule appears.
5. Press 1 (off) or 2 (on). The display flashes the entered selection. Press # and the display shows the new
setting for the selected schedule. Repeat the process until all desired outputs are attached to schedules.
Arming (0660nn where nn is schedule number)
Default setting is Off.
This setting lets you arm according to a time schedule.
Note:
This setting will allow you to arm to Away only. There is no disarm schedule.
To attach schedules to arming, do the following:
1. Press A or B until the display shows ATTACH SCHEDULES TO EVENTS.
2. Press # then A or B until the display shows ARMING.
3. To select arm to Away press #.
4. Press # and the display shows SCHEDULE 00 OFF/ON (current setting). If you want a different
schedule, press A or B until the schedule appears.
5. Press 1 (off) or 2 (on). The display flashes the entered selection. Press # and the display shows the new
setting for the selected schedule.
6. Repeat the process until all desired schedules are attached.

Energy saver menu

The Energy saver menu lets you set the energy saver module or dialog RF thermostat low- and high-setpoints.
These setpoints override the premises thermostat allowing the energy saver module or dialog RF thermostat to
activate the furnace/air conditioner.
Low setpoint (070)
Default setting is 50°F.
This setting determines the temperature at which the energy saver module relay closes to activate the furnace.

Hide quick links: