Tier 1 system programming menu
This section guides you through programming tier 1 System programming menu items as they appear in
sequence. The exact order you follow depends on whether you're installing a new system or changing
programming in an existing system.
Demo kit mode
Default setting is Off.
This setting determines whether you use your panel for a standard installation (off) or as a demo kit (on). When
the Demo kit option is on, only sensors learned into groups 01 and 03, duress code use, and phone test (
System Master
+
Code
2
settings:
•
Partition 1 master code = 1000
•
Partition 2 master code = 2000
•
User code 00 = 1001 (partition 1 code—you may use to jump to partition 2)
•
User code 01 = 1002 (partition 1 code—you may use to bypass sensors)
•
User code 02 = 2001 (partition 2 code—you may use for remote or offsite access)
•
User code 03 = 2002 (partition 2 code—you may use to perform system tests)
•
User code 04 = 1122 (partition 1 code—you may use to jump to partition 2, for remote or offsite
access, and system tests)
•
User code 05 = 2233 (partition 2 code—you may use to jump to partition 1, for remote or offsite
access, bypassing sensors, and system tests)
•
Partition 1 house code = 255 (P)
•
Partition 2 house code = 254 (O)
•
Zone 1 (hardwired input 1) = group 10, front door
•
Zone 2 (hardwired input 2) = group 13, bedroom window
•
Zone 3 (hardwired input 3) = group 17, living room motion sensor
•
Zone 4 (hardwired input 4) = group 1, panic
•
Zone 5 (wireless, keyfob, ID F00201) = group 01, (no text)
•
Zone 6 (wireless, DWS, ID A00206) = group 13, kitchen window
•
Comm failure = off, Demo kit = on
•
AVM code = 1212
•
Entry delay = 8 seconds
•
Exit delay = 8 seconds
•
Extended delay = 1 minute
•
Siren timeout = 2 minutes
To turn demo kit mode off or on, do the following:
1. With the display showing DEMO KIT MODE OFF/ON (current setting), press 1 (off) or 2 (on), then
press #.
2. The display flashes the entered setting, then stops after pressing # and displays DEMO KIT MODE
OFF/ON (new setting).
) are reported. Turning on this feature and doing a memory clear changes the following
Chapter 3
43
Programming
+
8