Aux power fail (06016)
Default setting is On.
When this setting is on, the panel sends a report to the central monitoring station if the 12 VDC power outputs
on the panel and/or SuperBus 2000 2-amp power supply fail.
Note:
If this feature is on and the AC failure and Low CPU battery features are both on, the panel sends AC failure and low
backup battery reports for the SuperBus 2000 2-amp power supply.
To turn the setting off or on, do the following:
1. With the display showing AUX POWER FAIL ON/OFF (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Ground fault (06017)
Default setting is On.
When this setting is on, the panel will annunciate and send a report to the central monitoring station if it detects
current flow between the panel's circuitry and the chassis. This indicates that a short to earth ground exists
somewhere in the system.
Note:
This feature must be on if hardwired smoke sensors are used in this system.
To turn the setting off or on, do the following:
1. With the display showing GROUND FAULT OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.

Reporting - partition 1 to 6 settings

The following describes the Reporting menu settings that appear under Partition 1 to 6.
Opening reports (06100 to 06600)
Default setting is Off.
When this setting is on, the panel sends an opening report to the central station after disarming the system.
Note:
To use this feature, the Open/close reports settings under the
specific CS phone or pager number.
To turn the setting off or on, do the following:
1. With the display showing OPENING REPORTS OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Closing reports (06101 to 06601)
Default setting is Off.
When this setting is on, the panel sends a closing report to the central station after arming the system.
Phones menu
on page 53 must be turned on for the