Check that the HOUSE dial on the X10 module matches the partition house code programmed into the
panel.
Panel is not powered by a power line carrier transformer. Replace existing transformer with a power line
carrier transformer.
Check to make sure X10 module is not plugged into an outlet controlled by a switch. Move to a
nonswitched outlet location and test.
Check that the lamp has a working bulb and that the lamp switch is on.
Power transformer and X10 modules are not plugged into outlets on the same electrical phase. Relocate
modules or transformer to different outlets to determine working locations.
Energy saver module issues
• Module does not respond to system commands or appear to control furnace.
Check that the module is wired correctly to the panel terminals.
Verify the module LED is flashing continuously. If the LED is not flashing, remove power and check
wiring.
There is a five minute delay after the module returns control to the furnace/AC thermostat, before the
module overrides the thermostat again. Wait five minutes and try again.
• Module temperature does not match actual room temperature.
The module room temperature setting has not been adjusted or was adjusted before the module warmed or
cooled to room temperature. To ensure accuracy, wait at least 15 minutes after installing the module before
adjusting the temperature. To adjust the module room temperature setting, see Temperature under the
ID (10000 to 10015)
Automation module issues
• Module is not controlling or communicating with the panel and panel indicates a "
where nn is the automation module bus unit number.
Check that the module is wired correctly to the panel terminals.
Verify the SuperBus module's red LED is flashing continuously. If the LED is not flashing, remove power
and check wiring.
Check that the RS-232 cable is firmly connected to the automation module and the automation device.
Verify the automation device is powered and turned on.
• Module is not controlling or communicating with the panel and panel does not indicate a bus failure.
Verify the automation module is learned into panel memory.
on page 93.
Unit-
"
BUS FAILURE UNIT nn