GE Security Concord 4 Installation Manual page 67

Ge security concord 4 security systems installation manual
Hide thumbs Also See for Concord 4:
Table of Contents

Advertisement

Low level reports (01032, 01042, 01052, 01062, and 01072)
Default setting is Off.
This setting determines whether the following nonalarm conditions report to a pager:
Force armed
Hardwired zone trouble (open or short)
Supervisory (wireless devices)
Low battery (wireless devices)
Phone test
Other nonalarm related conditions
To turn low-level reports on or off, do the following:
1. With the display showing LOW LEVEL RPTS OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the setting. Press # and the display shows the new setting.
Exception reports (01033, 01043, 01053, 01063, and 01073)
Default setting is Off.
This setting determines whether the panel reports to a pager if the system is not armed or disarmed at the
specified schedule times, if open/close reports are turned on. To turn exception reports off or on, do the
following:
1. With the display showing EXCEPTION RPTS OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Open/close reports (01034, 01044, 01054, 01064, and 01074)
Default setting is Off.
This setting determines whether opening and closing reports are sent to a pager. When turned on, the panel
sends a closing report when the system arms and an opening report when the system is disarms.
Note:
To use this feature, the opening reports and closing reports settings under the
turned on for that partition.
To turn opening/closing reports off or on, do the following:
1. With the display showing OPEN/CLOSE RPTS OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the setting. Press # and the display shows the new setting.
Latchkey reports (01035, 01045, 01055, 01065, and 01075)
Default setting is On.
This setting determines whether the panel reports to a pager when the system arms or disarms, according to
latchkey time scheduling. To turn latchkey reports off or on, do the following:
1. With the display showing LATCHKEY RPTS OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Reporting menu
on page 73 must be
Chapter 3