SP Mode Tables
5501
[PM Alarm Interval]
001 Printout
002 ADF
5504
[Jam Alarm]
Sets the alarm to sound for the specified jam level (document misfeeds are
not included).
001
[ 0 to 3 / 3 / 1 /step]
0: Zero (Off), 1: Low (2.5K jams), 2: Medium (3K jams), 3: High (6K jams)
5505*
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
error alarm counter decreases by "1" when any SC is not detected during
001
specified sheets of copies (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
[0 to 255 / 15 / 100 copies per step]
5507
[Supply Alarm]
001 Paper Size
003 Toner
128 Interval :Others
132 Interval :A3
B867
CTL
-
[ 0 to 9999 / 0 / 1 /step]
0: Alarm off
1 to 9999: Alarm goes off when the PM counter
reaches the specified value (1 to 9999) x 1000.
[ 0 or 1 / 1 / – ]
0: No alarm sounds
1: Alarm sounds after the number of originals passing
through the A(R)DF ≥ 10,000
CTL
-
CTL
-
0: Off, 1: On,
0: Off, 1: On,
[250 to 10000 / 1000 / 1 /step]