Ricoh B867 Manual page 37

Printer/scanner unit
Table of Contents

Advertisement

VM full error
[0766d]
B
Unexpected system memory size
Cache error
[4361]
B
Cache error in the CPU
The others
[----]
B
Error in OS
Self-Diagnostic Error: CPU
820
B
[0001-0015] [000A-000D]: Detailed error code
SM
DIMM.
2.
Check and/or replace the SD
card in slot 1 (lowest slot).
3.
Replace the controller.
See NOTE at the end of the SC
table.
Defective RAM DIMM
Defective SD card in slot 1
(lowest slot)
Defective controller
Software error
1.
Check and/or replace the RAM
DIMM.
2.
Check and/or replace the SD
card in slot 1 (lowest slot).
3.
Replace the controller.
See NOTE at the end of the SC
table.
Defective CPU
1.
Replace the controller board.
Defective memory
Defective flash memory
Defective CPU
1.
Replace the controller board.
27
Service Call Conditions
B867

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents