Ricoh B867 Manual page 39

Printer/scanner unit
Table of Contents

Advertisement

The pipeline clock frequency rate
is different from the prescribed
value.
[0702]: Detailed error code
The result when the program is
B
executed in the command cache
is different from desirable value.
[0709, 070A]: Detailed error code
Even you write the data in the
B
only cache of memory, the data is
actually written in another area
(not cache) of memory.
[0801, 0804, 0807, 0808, 0809, 80A]: Detailed error code
B
An error occurs when checking
the TLB.
[4002-4005]: Detailed error code
B
The calculation error in the CPU
occurs.
821
Self-Diagnostic Error: ASIC
ASIC error
[0B00]
B
The write-&-verify check error
has occurred in the ASIC.
ASIC not detected
[0B06]
B
The ASIC of the I/O is not
detected.
SM
Defective CPU devices
Mode bit data error, which is
used for initializing CPU.
1.
Replace the controller board.
Insufficient CPU cache
Insufficient memory process
speed
1.
Replace the controller board.
2.
Replace the RAM DIMM.
Defective CPU devices
Incorrect SPD
Boot mode setting error
1.
Replace the controller board.
2.
Replace the RAM DIMM.
Defective CPU devices
1.
Replace the controller board.
Defective CPU
1.
Replace the CPU.
Defective controller board
1.
Replace the controller.
ASIC (controller board
defective)