For example, to turn power on to power supply 0, type:
sc> poweron PS0
PS0: Powered on.
sc>
poweron Command Option
The poweron command uses one parameter: frulist.
Specifying the frulist option powers on the specified PSU.
TABLE 3-4
Value
PS0
PS1
removefru
Use the removefru command to prepare a field-replaceable unit (FRU) for removal
and to illuminate the corresponding OK-to-Remove LED on the switch.
Note – The software uses the same terms to refer to both FRUs and customer-
replaceable units (CRUs). The power supply units (PSUs) are the only field or
customer replaceable units.
▼
To Use the removefru Command
●
At the sc> prompt, type the following command:
sc> removefru fru
where fru is the name of the FRU or CRU you want to prepare for removal.
22
Sun IB Switch 9P Administration Guide • October 2006
poweron frulist Values
Description
Powers on power supply 0 in the switch.
Powers on power supply 1 in the switch.