showfru
Use the showfru command to display the contents of all FRU PROMs (field-
replaceable units with programmable read-only memory) in the switch.
▼
To Use the showfru Command
Note – You do not need user permission to use this command.
●
At the sc> prompt, type the following command:
sc> showfru fru
The single parameter of the command is a FRU list, that is, any combination of PS0,
PS1 and SSC0.
The following example shows sample output for the showfru command. This
example displays information about power supply unit 0.
CODE EXAMPLE 3-7
sc> showfru ps0
SEGMENT: SD
/ManR/UNIX_Timestamp32: Sat Jan 15 09:22:45 UTC 2005
/ManR/Fru_Description: POWER SUPPLY, A188
/ManR/Manufacture_Loc: BAO'AN,CHINA
/ManR/Sun_Part_No: 3001650
/ManR/Sun_Serial_No: 000013
/ManR/Vendor_Name: Astec Intl
/ManR/Initial_HW_Dash_Level: 02
/ManR/Initial_HW_Rev_Level: 01
/ManR/Fru_Shortname: A188 PSU
/SpecPartNo: 885-0250-02
/Configured_LevelR/Configured_Serial_No:
SEGMENT: FD
/InstallationR(2 iterations)
/InstallationR/UNIX_Timestamp32[0]: Sat Jan 01 00:00:12 UTC 2000
/InstallationR/Fru_Path[0]: SSC0/PS0
/InstallationR/Parent_Part_Number[0]: 5405185
/InstallationR/Parent_Serial_Number[0]: 000003
/InstallationR/Parent_Dash_Level[0]: 01
/InstallationR/System_Id[0]: 000003
/InstallationR/System_Tz[0]: 0
/InstallationR/Geo_North[0]: 0
Sample of the showfru Command