poweroff Command Options
The poweroff command uses the following options. See
Options" on page
poweroff Command Options
TABLE 3-3
Option
Description
Proceeds without prompting the following confirmation question:
-y
Are you sure you want to power off FRU PS{0|1} (y/n)?
Forces the poweroff regardless of the presence/availability of the other
-f
PSU. (Without this option the command will refuse to poweroff the PSU if
the other one is missing or failed.)
This option is equivalent to the removefru command
-r
Forces the poweroff regardless of the state of the switch. (For example,
-F
without this option powering off would not be permitted while ALOM is
logging to a PSU's FRUID.)
{frulist}
List FRUs to be powered off.
poweron
Use the poweron command to power on one of the two power supply units (PSUs).
▼
To Use the poweron Command
Note – You must have r level user permission to use this command. See
"userperm" on page 49
●
At the sc> prompt, type the following command:
sc> poweron
●
To turn on power to a specific FRU (field-replaceable unit) in the switch, type the
following command:
sc> poweron frulist
Where frulist is the name of the FRU you want to power on.
13.
for information on setting user permissions.
"Entering Command
Chapter 3 Command-Line Reference
21