Printer memory is full. Delete unnecessary formats or graphics from memory.
410
Parity mismatch.
411
Framing error (baud rate mismatch).
412
Flow control mismatch.
413
Online receive buffer is full. Check for a flow control problem.
611
Font, bar code, or density in the batch does not fit the format.
The data in this line of the batch is either missing or does not match the format.
612
613
Reference point off supply.
614
Portion of field off supply or there may be an invalid character in the packet.
703
The printer sensed a calibration of different-sized black marks. Make sure the
correct supply type is loaded.
704
Printer has not sensed a supply mark within the specified number of inches or is
out of supplies. Check the supply tracking, supply marks, black mark sensor
position, and supply roll for binding. Press Escape/Clear and try to continue
printing. Change supply.
715
Invalid data length/data mismatch. The data in the RFID Data Field has an
incorrect data length or there is a data type mismatch between selected data
type and actual data entered. This error also occurs when there is an error in
the Expanded C1Gen2 fields. Check with your System Administrator about your
format. Refer to the RFID Application Notes for more information.
727
Duplicate TID fields. The printer detected two inlays within the programmable
range with the same TID. One inlay is defective and another inlay may have the
wrong data encoded – do not use the label that has an overstrike pattern.
Check the Write power settings.
728
Multiple Tag Error. The printer detected multiple inlays within the programmable
range. Re-check values from the
729
Invalid Tag Type. The chip (inlay) embedded in your RFID supply does not
support serialized TID.
730
A memory allocation error occurred during initialization.
731
Backfeed error with a positive cut position defined for RFID. The tag is cut too
short and cannot backfeed to the correct inlay encoding position. Check or
modify the backfeed and cut position settings.
732
RFID Hardware Error. A non-RFID printer received a format containing an RFID
Data Field. Resend the format to an RFID printer.
733
The RFID tag is not in the programmable field with short-feed length RFID
supplies. Check supply loading. If you changed the supply, print or RFID
position, make sure the RFID tag was not moved out of the programmable
range. Refer to the
11-8 Operator's Handbook
Monarch® RFID Printer Setup
Monarch® RFID Printer Setup Utility
Utility.
for more information.