HORIZONTAL TERMINATIONS
TYPICAL CORNER INSTALLATION
90° elbow + horizontal pipe + termination cap.
VENTING DIMENSIONS FOR MINIMUM CORNER
Vent Opening Dimensions: Refer to vent pipe manufacturer's instructions
From Floor or Hearth to Vent Opening Center: 40-7/8" (1038 mm)
IMPORTANT: If top venting,
follow instructions on pages 20-
21 to convert fireplace from
rear vent ready to top vent
ready.
NOTE: Horizontal sections
require 1/4" (6 mm) rise for
every 12" (305 mm) of travel.
CAUTION: This gas appliance
must not be connected to or
joined with any other chimney
flue serving another appliance.
NOTE: Page 26 has information on restrictor installation in conjunction with
venting installation. Page 51 has information on restrictor recommendations
depending on burner flame appearance and instructions on installation after
venting is completed.