7.4 Horizontal Heat Shield Installation

IMPORTANT: The horizontal vent heat shield must be installed when
using a horizontal 45° elbow off the back of the appliance.
1.
Bend perforation on the (1) hand-tab down on the horizontal
vent heat shield.
2.
Locate the (2) screw holes located above the flue outlet on the
back of the fireplace.
3.
Align the (2) slots on the heat shield with the corresponding
(2) screw holes on the back of the fireplace. Secure with the
attachment screws (provided). The 1" (25mm) vent stand-off tab
will rest on top of the vent pipe.
FIGURE 7.2 Installed Heat Shield Assembly
46
#CLW-50-MV
R.1 October 2021
7.5 #800-WPT & #800-WPT2
Refer to section 3.5.2.3 and FIGURE 3.6 on page 16 for #800-WPT &
#800-WPT2 rough-in framing dimensions.
1.
2.
3.
4.
Vent Stand-o Tab
5.
Attachment Screws
FIGURE 7.3 #800-WPT & #800-WPT2 Installation
Installation Instructions
Measure wall thickness. Cut the included insulation to this
length.
Install wall pass-through section marked #1 (with 3/8" [10mm]
flange) into framed opening. Secure to interior wall with screws
(not provided). See FIGURE 7.3.
From the exterior, place insulation between flange and the top of
the framed opening in the wall pass-through section #1, cutting
as needed.
Install section marked #2 of wall pass-through into framed
opening, overlapping metal sections as necessary to
accommodate wall thickness. Secure to exterior wall with screws
(not provided).
Follow vent manufacturer installation instructions for vent
installation.
3/8" (10mm) ange must
be on interior wall
Insulation