7.7 Horizontal Vent Heat Shield Installation

IMPORTANT: The horizontal vent heat shield must be installed when
incorporating minimum horizontal venting.
1.
Loosen, but do not remove the (2) attachment screws in front of
the flue collar on the top of the fireplace.
2.
Bend the heat shield at perforation to a 90° angle.
3.
Slide the (2) slots on horizontal vent heat shield under previously
loosened screws.
4.
Re-tighten screws to install.
Figure 7.8, Installed Horizontal Heat Shield