Horizontal Heat Shield Installation - kozy heat Callaway 50 Series Installation And Operation Manual

Direct vent gas linear fireplace
Table of Contents

Advertisement

7.8 Horizontal Heat Shield Installation

IMPORTANT: The horizontal vent heat shield must be installed when
using a horizontal 45° elbow off the back of the appliance.
1.
Bend perforation on the (1) hand-tab down on the horizontal
vent heat shield.
2.
Locate the (2) screw holes located above the flue outlet on the
back of the fireplace.
3.
Align the (2) slots on the heat shield with the corresponding
(2) screw holes on the back of the fireplace. Secure with the
attachment screws (provided). The 1" (25mm) vent stand-off tab
will rest on top of the vent pipe.
Figure 7.3, Installed Heat Shield Assembly
46 VENTING
Vent Stand-o Tab
Attachment Screws
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
#CLW-50 R.4 November 2019