When not in use the plotter over the long term [CUSTODYwash]
When not in use the plotter over a week, perform "CUSTODYwash" function to clean the head
nozzle and ink discharge way.
After performing the function, store the plotter.
Cleaning tools
•
• Glove, Goggle
STEP
1. Push the [FUNCTION] key.
2. Push the [ ] and [ ] key until the display gives
the indication [MAINTENANCE].
3. Push the [ENTER] key.
[STATION] is displayed.
4. Push the [ ] and [ ] key until the display gives
the indication [CUSTODYwash].
5. Push the [ENTER] key.
The carriage moves to the platen.
6. Open the front cover.
7. Fill the cap with the cleaning fluid using a
pipette.
8. Close the front cover, and push the [ENTER]
key.
Pipette
- 5.16 -
FUNCTION
SET UP
< ENT >
FUNCTION
MAINTENANCE
< ENT >
MAINTENANCE
STATION
STATION
MENT : CUSTODYwash
STATION
COMPLETED
STATION
LEAVING
< ent >
: ent
: 1 min