5.12.4 Resetting the Gateway

Version 5.2
http://ArtTel.ru
The 'Maintenance Actions' screen enables you to remotely reset the gateway. Before you
reset the gateway, you can choose the following options:
Save the gateway's current configuration to the flash memory (non-volatile).
Perform a graceful shutdown. Reset starts only after a user-defined time expires or
after no more active traffic exists (the earliest thereof).
To reset the gateway, take these 5 steps:
Open the 'Maintenance Actions' screen (Maintenance menu).
1.

Figure 5-73: Maintenance Actions Screen

Under the 'RESET' group, from the 'Burn To FLASH' drop-down list, select one of the
2.
following options:
'Yes': The gateway's current configuration is burned (i.e., saved) to the flash
memory prior to reset (default).
'No': Resets the device without burning (i.e., saving) the current configuration to
flash (discards all unsaved modifications to the configuration).
Under the 'RESET' group, from the 'Graceful Option' drop-down list, select one of the
3.
following options:
'Yes': Reset starts only after the user-defined time in the 'Shutdown Timeout' field
(refer to Step 5) expires or after no more active traffic exists (the earliest thereof).
In addition, no new traffic is accepted.
'No': Reset starts regardless of traffic and any existing traffic is terminated at
once.