CHECKING SWITCH CONTINUITY

EAS00730
CHECKING SWITCH CONTINUITY
Check each switch for continuity with the pocket
tester. If the continuity reading is incorrect,
check the wiring connections and if necessary,
replace the switch.
CAUTION:
Never insert the tester probes into the cou-
pler terminal slots. Always insert the probes
from the opposite end of the coupler 1 tak-
ing care not to loosen or damage the leads.
NOTE:
S Before checking for continuity, set the pocket
tester to "0" and to the "Ω
S When checking for continuity, switch back and
forth between the switch positions a few times.
The terminal connections for switches (e.g.,
main switch, engine stop switch) are shown in
an illustration similar to the one on the left.
The switch positions a are shown in the far left
column and the switch lead colors b are shown
in the top row in the switch illustration.
NOTE:
"
between switch terminals (i.e., a closed circuit
at the respective switch position).
The example illustration on the left shows
that:
There is continuity between red and brown/blue
when the switch is set to "ON".
8-3
ELEC
Pocket tester
90890-03112, YU-3112
1" range.
" indicates a continuity of electricity